Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Hermitically Sealed Single Phase Kwh Meter MCB Surge Electric Meter Safety
The DDSY168-E is an economy type sinle phase prepayment meter. It is built in keypad based compact BS footprint housing equiped with a extended transparent terminal cover fitting with MCB. The meter is a cost-effective controller for revenue collection and credit dispensing in low voltage residential environments. Thanks to its dynamic range of 5(80)Amp current and 30Vm Rf withstand immunity, the meter is operatable even in very harsh environments.
The DDSY168-E upper closure is made of poly-carbonate flame retardant material ,hermitically sealed against illegal intrusion. It isintended for rich metering features to provide a broad range of information such as V, A, PF, P, balance. It also supports tamper detection and SRE (significant reverse energy) measurement for active energy.
The meter provides a metal backplate fixture . This feature enables the meter to be tightly fixed agaisnt the mounting surface to prevent tamper and sabtage.
Major Features
a) Display trip status
b) Programmable power limit and low credit warning
c) Unidirectional measurement for active energy
d) Display valuable meter information by inputting short codes
e) Optical port data output
f) IP 54 rating
g) Surge protection for up to 13kV lightening
Key benefits
1) Low cost and easy to deploy and maintenance
2) Compact, and durable
3) Tamper proof for revenue protection
4) LED consumption indicator
5) Muti-rate and holiday setting
Specifications:
Nominal voltage Un |
220/230/240 V |
Limited voltage |
70%~120%Un |
Nominal frequency fn |
50-60Hz+5% |
Basic current(Ib) |
5-10A |
Maximum current(Imax) |
60-100A |
Starting current(Ist) |
20mA |
Active energy constant |
1000imp/kWh |
Accuracy as Active energy to IEC6205321 |
Class1.0 |
Power consumption in Voltage circuit |
<2W <8VA |
Power consumption in current circuit |
<1VA |
Operating temperature |
25 to+70 |
Storage temperature |
40 to+85 |
Insulation level |
4kV rms for 1min |
Impulse voltage withstand |
8kV, 1.2/50 μs |
Air discharge |
16kV |
Immunity to HF fields |
|
80MHz to 2GHz with load |
10V/m |
100kHz to 1GHz without load |
30V/m |
Fast transient burst test |
4kV |
Meter shell Protection Rate |
IP54(IEC60529) |
Insulation System Classification |
Protective Class II |
ShenzhenCalinmeterCo LTD [China (Mainland)]
Business Type:Manufacturer
City: Shenzhen
Province/State: Guangdong