ShenzhenCalinmeterCo LTD
|
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Prepaid Wireless Smart Meters Card Type 3X240V Kilowatt Hour Meter 3 Phase
The CA368-C is a three phase four wire CPU card type prepayment smart electric meter. It is built for commercial and industrial electric metering applications.The meter is a new generation that combines latest metrology features with 3DES security encrypti Thanks to this increased security, consumer is given secured convenience. The meters provide a full house of features and functionality and efficiently handles load up to 100A per phase. The CA368-C can work as a good revenue protection device for complex owners and utilities.
Plug-in modular design is another major feature of the CA368-Co. The module is for data transmission and communications purpose .By using this design, a utility can always choose most cost-effective communication according to local infrastructure conditions. PLC/RF/GPRS/3G and 4G LTE cellular data networks are recommended ones for metering section. There will be no need for utility to pay extra to add whatever functions they will not use.
Features
a) Complete data security
b) tandardized metering process
c) MD measurement and load profile history
d) Tamper detection for magnetic field, reverse connection, cover open , etc.
e) Data retention in outage,
f) TOU with multi-rate and multi billing cycles
g) IEC 62056-21 and DLMS/COSEM compliant
Utility Benefits
1) Load control on demand and remote
2) Reduce operational and maintenance costs
3) Free selection of communication network
4) Enhanced revenue protection by flexible consumer contract control
5) Long life time with easy upgrade features
Specifications:
Electrical parameters |
|
---|---|
Nominal voltage Un |
3x240V |
Limited voltage |
60%~120%Un |
Frequency |
50/60Hz+5% |
Basic current(Ib) |
10A |
Maximum current(Imax) |
100A |
Starting current(Ist) |
30mA |
Active energy constant |
400imp/kWh |
Accuracy |
|
Active energy to IEC6205321 |
Class1.0 |
Reactive energy to IEC6205323 |
Class2.0 |
Power Consumption |
|
Power consumption in Voltage circuit |
<2W <8VA |
Power consumption in current circuit |
<1VA |
Temperature range |
|
Operation meter |
25 to+70 |
Storage |
40 to+85 |
|
|
Insulation strength |
|
AC Insulation strength |
4kV at 50Hz during 1min |
Impulse voltage 1.2/50μs mains connections |
8kV |
|
|
Electro Magnetic Compatibility |
|
Electrostatic discharges |
|
Contact discharge |
8kV |
Air discharge |
16kV |
Electromagnetic RF fields |
|
27MHz to 500MHz typical |
10V/m |
100kHz to 1GHz typical |
30V/m |
Fast transient burst test |
4kV |
Mechanical requirements |
|
Protection Rating |
IP54 |
Insulation Classification |
Protective Class II |
Maximum cable size |
10 mm |